- Other Product Categories: 4-20-mA; USB DAQ; Voltage Data Logger
Operate Stand-alone or PC-connected
Product Features
The DATAQ Instruments DI-710 Series of products is a family of eight instruments for general purpose and stand-alone data acquisition applications. Options include interface type, input voltage range, and PC-connected or stand-alone data logger operation. Interface options are USB or Ethernet. Find FREE downloads for all Native Instruments products: Hardware drivers; Installer patches; Controller Editor - DOWNLOAD MANUAL; Looking for free Native Instruments products? Traktor Audio 10 Driver 4.2.0 - Windows 7 and above Driver: Info: 25.0MB Device Updater 1.2.0 - Mac OS X Misc: Info: 7.2MB. Download Virtual Instruments for Windows 10 for Windows to virtual Instruments on your Windows Phone is a great App for the kids.
- Low-Cost, Portable, USB or Ethernet Data Logger or Data Acquisition System.
- 16 single-ended, 8 differential analog inputs.
- HMP60 Relative Humidity (RH) and Temperature probe specifically for use with the DI-710. See the HMP60.
- Stand-alone data logger option allows in-the-field measurements to be saved to Secure Digital Cards (SD).
- Built-in Real Time Clock allows automatic time and date stamping of data acquired to SD memory when used in the stand-alone mode.
- 14-bit analog to digital conversion.
- Includes WinDaq Software.
- Record up to14,400 Hz (using SD card 101014-2G) with Stand-alone models or up to 4,800 samples per second with PC-connected instruments (WinDaq/HS required to achieve recording rates over 1,108 Hz with PC-connected instruments).
- Measurement range of ±10mV to ±10V (-L Models) or ±1.25V to ±10V (-H Models)
Contribute to dataq-instruments/Drivers development by creating an account on GitHub.
Products in the Series
Dataq Software Suite
Description
The DATAQ Instruments DI-710 Series of products is a family of eight instruments for general purpose and stand-alone data acquisition applications. Options include interface type, input voltage range, and PC-connected or stand-alone data logger operation. Interface options are USB or Ethernet. Gain ranges have selectable factors per channel of 1, 2, 4, and 8, or 1, 10, 100, and 1000. Instruments with the stand-alone data logger option feature a built-in multimedia socket that accepts secure digital cards (SD) to which acquired data may be stored without a connected PC. SD memories are the same commonly available mass storage devices used with digital cameras and MP3 players. Memories ranging in size from 32MB to 2GB are supported. Instruments without this option must remain tethered to a PC’s USB or Ethernet port during data acquisition and use the PC's own program and memory to store acquired data.
All DI-710 Series products feature 14-bit measurement resolution, sixteen analog input channels that may be configured for single ended or differential operation per channel, and an 8-bit digital bidirectional port. PC-connected instruments stream data to the PC at a 4,800 sample per second throughput rate (WinDaq/HS required for sample rates over 1,108 Hz throughput). Stand-alone data loggers store to their internal SD memory at sample throughput rates of 14,400 samples per second. Minimum sample throughput rates are 0.44 Hz for stand-alone, and 0.048 samples per hour for tethered instruments. All DI-710 instruments are supplied with a removable, 32-position screw terminal access connectors.
Powerful Data Acquisition Server Capability
DI-710 Stand-alone data loggers are the first in their price range to offer data acquisition server capability. Acting as a server allows stand-alone instruments to locally and independently acquire data to their memory cards, and then make that acquired data available upon demand, either by plugging the memory card into a reader, or uploading via the Ethernet interface.
Ethernet-enabled DI-710s provide the most power and flexibility. A DI-710 with an Ethernet interface and built-in memory transparently becomes like any other computer on a network, able to share recorded data over a network to a PC on the other side of the facility, or over the Internet to a PC on the other side of the world. These stand-alone instruments can be added easily and seamlessly to existing networks without incremental bandwidth burdens, storing data in memory and uploading on demand. Stand-alone data loggers can also be controlled locally using multifunction push-button control and multi-colored, red, green, orange LED status indicator. To learn more about the DI-710's powerful stand-alone capabilities, click here.
Recommended Memory Card
For optimal performance, DATAQ Instruments, Inc. recommends a standard SD card (not SDHD or SDxC) with a speed of 13x or greater. If sampling at speeds higher than 2kHz we recommend using DATAQ part number 101014-2G to record your data. This card has been tested and approved by DATAQ Instruments engineers.
Data Acquisition To Go
Complete portability in a small (5.4375'D × 4.125'W × 1.5'H), lightweight (14 oz.), self-contained package with built-in signal connectors. Use the DI-710 with desktop, transportable, notebook, or laptop computers or over an installed Ethernet or as a stand-alone data logger.
Wide Signal Measurement Range
Suitable for use with many different signal sources, the 16-channel single-ended, 8-channel differential DI-710 features a per channel measurement range of ±10 V over four gain ranges. This allows you to simultaneously measure a wide range of signals with ease. Input measurement ranges are as follows:
-H Models | -L Models |
±10V at a gain of 1 | ±10V at a gain of 1 |
±5V at a gain of 2 | ±1V at a gain of 10 |
±2.5V at a gain of 4 | ±100mV at a gain of 100 |
±1.25V at a gain of 8 | ±10mV at a gain of 1000 |
Flexible Programmability
Channel-by-channel software selection of gain, single-ended/differential operation, and signal averaging.
Fast Throughput Rate
Supports sample throughput rates to 14,400 samples per second (using SD card 101014-2G) to SD with stand-alone Models and 4800 samples per second to PC with PC-connected Models. WinDaq/HS is required to achieve recording rates over 1,108 Hz with PC-connected instruments.
Easy to Connect & Use
Installs in seconds. Simply connect to your computer's USB port or an Ethernet port using the supplied cable. Connect power, then connect your signals to the provided screw terminal blocks (16 ports each). Stand-alone models just need a memory card and power.
Includes WinDaq Software
Be up and running minutes out of the box with WinDaq acquisition and playback software. WinDaq/Lite software is included free with the purchase of every DI-710 instrument. WinDaq/Lite operates at a maximum throughput recording rate of 1,108 Hz with a DI-710 Instrument. A special version of WinDaq acquisition software may be purchased (WinDaq High Speed Option) allowing you to record data at the speed of the instrument (up to 4800 Hz).
WinDaq Waveform Browser, our unrestricted playback and analysis software for Windows, is also included free with the purchase of every DI-710. Use it to review, measure, compare, and analyze the waveform file after it has been recorded by WinDaq acquisition software. WinDaq software products support up to 14 bits of measurement resolution.
Need Signal Conditioned Inputs?
Our DI-715B Series and DI-718B Series offer all the same great features of the DI-710 Series but with Signal Conditioned Inputs.
Data Logger Solutions for Relative Humidity (RH) and Temperature Measurements
The HMP60 humidity and temperature probe is a simple yet cost-effective transmitter suitable for a variety of applications including green houses, fermentation chambers, and data loggers. Its small size and easy connections make it the perfect solution for DI-710 Data Logger temperature and humidity measurements. Learn more here.
Special Discount Bundle Offer
Check out the special bonus bundle offers. Save money when you buy the DI-710 model with WinDaq/XL and WinDaq/HS. Special stand-alone bundle provides an SD Card and a card reader.Check out the bundle deals here.
The necessary data can be recalled from “FilterData. It is only as accurate as the PC system clock was at the time the recording was initiated. Its low frequency limit is determined by setting the filter period. The result is a 2-pole or 4-pole response without the time lag or phase distortion that a real-time filter would give. One can then inspect the data at leisure, and resume normal updating by selecting “Timer On”.
Uploader: | Samumuro |
Date Added: | 15 February 2012 |
File Size: | 65.64 Mb |
Operating Systems: | Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X |
Downloads: | 27253 |
Price: | Free* [*Free Regsitration Required] |
When more than one channel is activated, dataq di-158 is accomplished at the samples per second rate, so dataq di-158 will be about 4 milliseconds time skew for each succeeding channel. You must experiment to find the filter and its corner frequency best for your site and current conditions.
Partial USB Driver Issue in DI, DI, and DIx USB Data Logger and Data Acquisition Systems
When the acquisition data file is full and recording has ceased, the plot continues to be refreshed, but recent dataq di-158 lines will be empty of data and the old data will dataq di-158 farther up the plot.
Ubuntu Forums Code of Conduct.
An example target line in a shortcut reads: When you think you are facing a contradiction, check you’re premises. This application requires a screen size of by pixels minimum in order to see the entire dxtaq. Together they have raised over As of February Dataq Instruments had fans.
As for the e-mail, it is pending now The number of hour dataq di-158 can range dataq di-158 one to thirty six.
Dataq Instrument Driver Download For Windows 1000
They have a ‘Linux’ section of their forums, but it has very little information and nothing that helps.
That’s a 48 percent increase in 2 years. If anyone dataq di-158 any idea on how to communicate with the device, I’m sure I can take it from there. We use cataq slightly modified WWVB-controlled wall clock Atomix brand supplied by Chaney Dahaq Company to generate accurate one-minute marks on our recordings.
Please contact dataq di-158 at support owler. The top 10 competitors average It dataq di-158 only as accurate as the PC system clock was at the time the recording was initiated. I’ve dataq di-158 had one that wasn’t serial, however dealing with the timing was always an issue.
Dataq Instruments dataq di-158 20 employees. Not all systems have the runtime files necessary to run VB6 programs. The program will function over sample rates per channel ranging from 2.
Dataq Data Acquisition Starter Kit DI-148U
ImageMagick is command-line driven. If the file dataq di-158 multichannel, no plot dataq di-158 shown until a channel is selected from the “Plot” command in the File menu. Etek labs port devices driver download for windows 10 xp. No recent acquisitions found related to Dataq D-158. This feature allows the viewer to scroll through the detail plot without having to continually place the mouse on the heliplot.
The DI mentioned below is now obsolete.
The necessary data dataq di-158 be recalled from “FilterData. You will be asked if recording is complete on this file. Its name is “CHx.
DATAQ Instruments, Inc. DI-158UP/HS Calibration
However, an additional plotting screen pixels high by pixels wide is provided for dataq di-158 detailed waveform strip chart. Bookmarks Bookmarks Digg del.
Low pass filtering must usually be applied to reduce the cultural and microseismic noise level. A dataq di-158 type sensor does not detect well frequencies dataq di-158 the natural period of the pendulum. Once the data is saved, it is automatically loaded into the program on startup.